Discontinued
Mountz 079010 MTX80z Low Torque Reaction Sensor. Model: MTX80z Drive Size: 1/4” F/Sq American: 8 – 80 ozf.in S.I.: 5.7 – 56.5 cN.m Metric: 0.6 – 5.8 kgf.cm Tool Length: 2.55” Tool Width: 1.6” Tool Height: 1”
Discontinued
Mountz 079010 MTX80z Low Torque Reaction Sensor Description:
The Mountz 079010 MTX80z Low Torque Reaction Sensor is designed to facilitate the accurate testing of multiple torque ranges, essential for tools used in production, maintenance, and calibration labs. This versatility makes it a valuable asset for various industrial applications.
As a static, reaction-type sensor, the Mountz 079007 MTX10z is particularly suited for use with small hand or power torque screwdrivers and wrenches. Its design ensures reliable and accurate measurements, vital for maintaining tool precision in demanding industrial settings. To ensure longevity and integrity, operators must use a mini run-down adapter when testing power tools. This precaution prevents damage to the sensor and guarantees accurate readings over time.
For optimal performance, the Mountz 079010 MTX80z Low Torque Reaction Sensor is designed to be bench-mounted. This setup provides a stable and secure environment for precise torque measurements, which is crucial in maintaining the accuracy of the testing process.
The Mountz 079010 MTX80z Low Torque Reaction Sensor integrates seamlessly with Mountz LTT and PTT torque analyzers through a required cable connection, utilizing plug-and-play ARC II technology. This feature simplifies the process of connecting and switching between up to four sensors, enhancing the efficiency of quality and calibration teams.
Regularly auditing and validating tooling calibration with the Mountz 079010 MTX80z Low Torque Reaction Sensor is essential for minimizing errors in assembly processes and preventing product defects. This practice is crucial for manufacturers who prioritize product quality, safety, and reliability.
The Mountz 079010 MTX80z Low Torque Reaction Sensor is an essential tool for measuring, testing, and calibrating hand and power tools to ensure the correct application of torque. Its ease of use, compatibility with Mountz torque analyzers, and the inclusion of an ISO 17025 calibration certificate with the analyzer purchase make it an invaluable asset for enhancing assembly line accuracy and reducing manufacturing errors.
Mountz 079010 MTX80z Low Torque Reaction Sensor requires companion item: Mountz 072003 Cable MTX to PTT and LTT
Part Number | 079010 |
---|---|
Model | MTX80z |
Drive Size | 1/4'' F/Sq |
American | 8 – 80 ozf.in |
S.I. | 5.7 – 56.5 cN.m |
Metric | 0.6 – 5.8 kgf.cm |
Tool Length | 2.55'' |
Tool Width | 1.6'' |
Tool Height | 1'' |
Cal Cert Options Data Set | Supplied with a Free ISO 17025 Certification of Calibration |
The Mountz 079010 MTX80z Low Torque Reaction Sensor is designed to facilitate the accurate testing of multiple torque ranges, essential for tools used in production, maintenance, and calibration labs. This versatility makes it a valuable asset for various industrial applications.
As a static, reaction-type sensor, the Mountz 079007 MTX10z is particularly suited for use with small hand or power torque screwdrivers and wrenches. Its design ensures reliable and accurate measurements, vital for maintaining tool precision in demanding industrial settings. To ensure longevity and integrity, operators must use a mini run-down adapter when testing power tools. This precaution prevents damage to the sensor and guarantees accurate readings over time.
For optimal performance, the Mountz 079010 MTX80z Low Torque Reaction Sensor is designed to be bench-mounted. This setup provides a stable and secure environment for precise torque measurements, which is crucial in maintaining the accuracy of the testing process.
The Mountz 079010 MTX80z Low Torque Reaction Sensor integrates seamlessly with Mountz LTT and PTT torque analyzers through a required cable connection, utilizing plug-and-play ARC II technology. This feature simplifies the process of connecting and switching between up to four sensors, enhancing the efficiency of quality and calibration teams.
Regularly auditing and validating tooling calibration with the Mountz 079010 MTX80z Low Torque Reaction Sensor is essential for minimizing errors in assembly processes and preventing product defects. This practice is crucial for manufacturers who prioritize product quality, safety, and reliability.
The Mountz 079010 MTX80z Low Torque Reaction Sensor is an essential tool for measuring, testing, and calibrating hand and power tools to ensure the correct application of torque. Its ease of use, compatibility with Mountz torque analyzers, and the inclusion of an ISO 17025 calibration certificate with the analyzer purchase make it an invaluable asset for enhancing assembly line accuracy and reducing manufacturing errors.
Mountz 079010 MTX80z Low Torque Reaction Sensor requires companion item: Mountz 072003 Cable MTX to PTT and LTT
Part Number | 079010 |
---|---|
Model | MTX80z |
Drive Size | 1/4'' F/Sq |
American | 8 – 80 ozf.in |
S.I. | 5.7 – 56.5 cN.m |
Metric | 0.6 – 5.8 kgf.cm |
Tool Length | 2.55'' |
Tool Width | 1.6'' |
Tool Height | 1'' |
Cal Cert Options Data Set | Supplied with a Free ISO 17025 Certification of Calibration |